Prince
P-72 Styrene Copolymer
Solvent Cement & Primer
Estimated Quantities of Prince P-72 Cement* for Socket Welding Per Quart
* Estimated quantities of Prince P-72 cement can vary due to installation conditions, tolerance variations, and socket depth; consequently, this information should be used as a guide not a guarantee. Prince
P-72 Cement Socket Ends System Maximum
P-72
Temperature Correction Factors
To obtain pressures at elevated temperatures, please multiply the above correction factor at desired temperatures by the maximum operating pressure at 73° F as shown on Table III. Flanged
End System Maximum Operating Pressure PSI
|
Support Spacings - Schedule 40 - P-72 Pipe
| Temp:
°F |
60 |
80 |
100 |
120 |
140 |
160 |
180 |
200 |
| INCHES |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
| 1/4 |
4 |
3-3/4 |
3-1/2 |
3-1/4 |
2-3/4 |
2-1/2 |
2 |
1-1/2 |
| 1/2 |
4-1/2 |
4-1/4 |
4 |
3-3/4 |
3-1/4 |
3 |
2-1/2 |
2 |
| 3/4 |
5 |
4-3/4 |
4-1/2 |
4-1/4 |
3-3/4 |
3-1/4 |
2-3/4 |
2 |
| 1 |
5-1/2 |
5-1/4 |
4-3/4 |
4-1/2 |
4 |
3-1/2 |
3 |
2-1/4 |
| 1-1/4 |
6 |
5-1/2 |
5-1/4 |
4-3/4 |
4-1/4 |
3-3/4 |
3-1/4 |
2-1/4 |
| 1-1/2 |
6-1/2 |
6 |
5-1/2 |
5 |
4-1/2 |
4 |
3-1/2 |
2-1/2 |
| 2 |
7 |
6-1/2 |
6 |
5-1/2 |
5 |
4-1/4 |
3-3/4 |
2-3/4 |
| 2-1/2 |
7-1/2 |
7-1/4 |
6-3/4 |
6-1/4 |
5-1/2 |
4-3/4 |
4 |
3 |
| 3 |
7-3/4 |
7-1/2 |
7 |
6-1/2 |
6 |
5-1/4 |
4-1/4 |
3-1/4 |
| 4 |
8-1/4 |
8 |
7-1/2 |
7 |
6-1/4 |
5-1/2 |
4-3/4 |
3-1/2 |
| 6 |
8-3/4 |
8-1/2 |
8 |
7-1/2 |
6-3/4 |
6 |
5 |
4 |
| 8 |
9-1/4 |
9 |
8-1/2 |
8 |
7-1/4 |
6-1/2 |
5-1/2 |
4-1/4 |
| 10 |
9-3/4 |
9-1/2 |
9 |
8-1/2 |
7-3/4 |
7 |
6 |
4-1/2 |
| 12 |
10-1/4 |
10 |
9-1/2 |
9 |
8-1/4 |
7-1/2 |
6-1/2 |
4-3/4 |
Support Spacings - Schedule 80 - P-72 Pipe
| Temp:
°F |
60 |
80 |
100 |
120 |
140 |
160 |
180 |
200 |
| INCHES |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
Feet |
| 1/4 |
4 |
4 |
3-3/4 |
3-1/2 |
3-1/4 |
2-3/4 |
2-1/2 |
2 |
| 1/2 |
5 |
4-3/4 |
4-1/2 |
4-1/4 |
3-3/4 |
3-1/4 |
3 |
2-1/4 |
| 3/4 |
5-1/2 |
5-1/4 |
5 |
4-3/4 |
4-1/4 |
3-1/2 |
3-1/4 |
2-1/2 |
| 1 |
6 |
5-3/4 |
5-1/2 |
5 |
4-1/2 |
4 |
3-1/2 |
2-3/4 |
| 1-1/4 |
6-1/2 |
6-1/4 |
5-3/4 |
5-1/4 |
4-3/4 |
4-1/4 |
3-3/4 |
2-3/4 |
| 1-1/2 |
6-3/4 |
6-1/2 |
6 |
5-1/2 |
5 |
4-1/2 |
4 |
3 |
| 2 |
7-1/2 |
7 |
6-1/2 |
6 |
5-1/2 |
4-3/4 |
4-1/4 |
3-1/4 |
| 2-1/2 |
8-1/4 |
7-3/4 |
7-1/2 |
7 |
6-1/4 |
5-1/2 |
4-1/2 |
3-1/2 |
| 3 |
9 |
8-1/2 |
8 |
7-1/2 |
6-3/4 |
5-3/4 |
5 |
4 |
| 4 |
9-3/4 |
9-1/4 |
8-3/4 |
8 |
7-1/4 |
6-1/4 |
5-1/4 |
4-1/4 |
| 6 |
10-1/4 |
9-3/4 |
9-1/4 |
8-1/2 |
7-3/4 |
6-3/4 |
5-3/4 |
4-1/2 |
| 8 |
10-3/4 |
10-1/4 |
9-3/4 |
9-1/4 |
8-1/2 |
7-1/2 |
6-1/2 |
5-1/4 |
| 10 |
11-1/4 |
10-3/4 |
10-1/4 |
9-1/2 |
8-3/4 |
7-3/4 |
6-3/4 |
6 |
| 12 |
11-3/4 |
11-1/4 |
10-3/4 |
10 |
9-1/4 |
8-1/4 |
7-1/4 |
6-1/2 |
The
above data is based on fluids with a specific gravity
of 1.0.
For heavier fluids, the support spacing from the charts
should be multiplied by the following correction factor:
|
Sp. Gr. |
Correction Factor |
|
| 1.0 |
1.00 |
|
| 1.1 |
0.98 |
|
| 1.2 |
0.96 |
|
| 1.4 |
0.93 |
|
| 1.6 |
0.90 |
|
| 2.0 |
0.85 |
|
| 2.5 |
0.80 |
For support spacing at higher temperatures than listed, please consult us.
|
|
|
|||
|
||||
|
|
|